[:it]Yokogawa 155 Clamp-on Tester, AC, True RMS, 2000A[:]

[:it]AC TRUE RMS CLAMP-ON TESTER FOR AC CURRENT

CL Series consists of AC, AC/DC, and leakage current clamps with various ranges and dimensions. The multiple options include RMS, Mean, Temperature, frequency, and recorder output.

 

yokogawa

[:]

Categoria:
Richiedi Informazioni

[:it]

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • True RMS display
  • 54mm in diameter of measurable conductor
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. HI 600 V, CAT. II1000 V)
Display (LCD, Digital Counts) 3999
AC Current Accuracy (400A Reference) 1.0+3(50/60Hz)
2.0+3(40~1kHz)
AC Current Accuracy (2000A Reference, 0~1500A) 2.0+3(50/60Hz)
3.0+3(40~1kHz)
AC Voltage Accuracy (40/400V/750V Reference) 1.0+2(50/60Hz)
1.5+3(40~1kHz)
DC Voltage Accuracy (40/400V/1000V Reference) 1.0+2
Resistance Accuracy (400/4k/40k/400kO reference) 1.5+2, Beeps at below 50± 35O (continuity check)
DC Output Accuracy (400A, 0~400mV Reference) ?.5% rdg ± 0.5mV (50/60Hz)
?.5% rdg ± 0.5mV (40~1kHz)
Method of detection True RMS
Response Time Approx. 2 seconds
Range Switching Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)
Data hold On all range
Operating temperature and humidity 0-40°C, 85% RH or less (no condensation)
Influence of external magnetic field 1A or less at 400A/m
Influence of conductor position ± (2.0% rdg + 3dgt) or less
Safety Standard Conforms EN 61010-1, EN61010-2-031, EN61010-2-032
Circuit voltage 1000Vrms or less
Withstanding voltage 5.55kV AC for one minute
Power Supply R6P(SUM-3)x2 or LR6x2
Battery Life1 150 hours
Consumed current Approx. 5mA
Sleep Function Automatically powered down in about 10 minutes after the last switch operation
Diameter of measurable conductor 54mm at maximum
Dimensions Approx. 105(W)x247(H)x49(D)mm
Weight (Approx.) 470g
Accessories Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011) User’s manual (IM CL120), batteries
Order Notes Each item selected MUST be ordered as a separate line item.
Product Notes All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

[:]

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “[:it]Yokogawa 155 Clamp-on Tester, AC, True RMS, 2000A[:]”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *